Skip to content
HubwiseHome

Air purifier room size calculator (CADR)

CalculatorUpdated By the Hubwise Home team

Enter your room’s length, width and ceiling height to see the CADR in cfm to look for, compare it with the EPA’s two-thirds rule for smoke, and check an air cleaner you already own.

As an Amazon Associate we earn from qualifying purchases. Product links on this page are affiliate links: buying through them costs you nothing extra and does not change what we recommend.

Coway Airmega AP-1512HH product photo
Our pick for this page

Coway Airmega AP-1512HH

Best for: Bedrooms and living rooms with allergies or wildfire smoke.

  • Long-standing model with easy-to-find filters
  • Auto mode
  • Not app-connected
  • Filters are a recurring cost

Name, photo and listed features checked on Amazon.com on November 14, 2026. We have not tested it; see how we choose.

Choosing a room fills in the size
feet (ft)
feet (ft)
feet (ft), 8 ft is typical
How many times per hour the room’s air passes through the filter
cfm, smoke CADR from the label

Next steps

How the calculation works

CADR stands for clean air delivery rate: the volume of filtered air, in cubic feet per minute (cfm), that an air cleaner delivers for a given kind of particle. The EPA says the number is meant to help you choose an air cleaner for the size of the room. The calculator finds the CADR you need in three steps:

  1. Floor area = length × width, in square feet.
  2. Room volume = floor area × ceiling height, in cubic feet.
  3. CADR needed = volume × air changes per hour (ACH) ÷ 60, rounded up to the next 5 cfm. Dividing by 60 turns hours into minutes.

Two worked examples, which match the calculator’s display:

  • Bedroom, 12 × 12 ft, 8 ft ceiling, 4 ACH. Area 144 sq ft, volume 1,152 cu ft. CADR = 1,152 × 4 ÷ 60 = 76.8 cfm, so look for about 80 cfm. The EPA’s two-thirds rule gives 96 cfm for smoke.
  • Living room, 15 × 20 ft, 9 ft ceiling, 5 ACH. Area 300 sq ft, volume 2,700 cu ft. CADR = 2,700 × 5 ÷ 60 = 225 cfm. The EPA rule gives 200 cfm at 8 ft, and 225 cfm when scaled to a 9 ft ceiling.

What the EPA says

The EPA’s guide to air cleaners lists minimum CADR by room size, assuming 8 ft ceilings: 65 cfm for 100 sq ft, 130 cfm for 200 sq ft, 195 cfm for 300 sq ft, 260 cfm for 400 sq ft, 325 cfm for 500 sq ft and 390 cfm for 600 sq ft. Its wildfire guidance says to choose a unit whose smoke CADR is at least two-thirds of the room’s area in square feet. At an 8 ft ceiling, two-thirds of the floor area is exactly 5 air changes an hour (area × 8 × 5 ÷ 60), which is why the calculator offers 5 ACH as the smoke setting. The EPA also says that rooms with higher ceilings need a higher CADR; the scaled figure here simply adjusts the rule in proportion to ceiling height, which is our own arithmetic, not an EPA formula.

Common mistakes

  • Trusting “covers up to” claims. Box claims can assume fewer air changes than you want. Compare the CADR number with your target.
  • Using the dust or pollen CADR for smoke. Smoke particles are smaller. Choose the unit by its smoke CADR where one is listed.
  • Forgetting ceiling height. A 300 sq ft room with a 12 ft ceiling holds 50% more air than the same room at 8 ft.
  • Running on low. CADR ratings are typically measured at a unit’s high speed. On its quietest setting it delivers less than its rated flow.
  • Ignoring doors. The numbers assume a closed room. An open door means you are cleaning part of the house.
  • Choosing an ozone generator. The EPA advises avoiding air cleaners that intentionally produce ozone, which is a lung irritant.
  • Skipping filter changes. The EPA notes that a dirty, overloaded filter will not work well and that manufacturers typically recommend replacement every 60 to 90 days; follow your model’s schedule.

A calculator cannot promise a result for your health or allergies. It helps you match a unit to the room. Use an air quality monitor to see whether particle readings actually fall. For smoke season, see wildfire smoke and indoor air; for a full shopping list, see the allergy air quality kit.

Frequently asked questions

What CADR do I need for a 12 × 12 foot bedroom?

At 4 air changes an hour and an 8 ft ceiling the room needs about 80 cfm. The EPA’s smoke rule of two-thirds of the floor area gives about 96 cfm. A unit rated for 100 cfm or more covers both.

What is the difference between CADR and ACH?

CADR is how much clean air a unit delivers per minute, in cfm. ACH is how many times per hour a room’s whole volume of air passes through it. ACH = CADR × 60 ÷ room volume.

Does ceiling height matter for air purifier sizing?

Yes. The EPA’s CADR table assumes an 8 ft ceiling and advises a higher CADR for taller ceilings. The calculator scales the target with the room’s volume.

Sources

  1. U.S. EPA — Guide to air cleaners in the home
  2. U.S. EPA — Wildfires: indoor air filtration
  3. Amazon.com listing: COWAY Air Purifier for Home Up to 1,748ft², HEPA Filter for Smoke, Allergies, Pet Dander, (ASIN B00BTKAPUU), checked November 14, 2026

Product names, photos and listed features were checked on the Amazon.com product pages on November 14, 2026. Prices and availability change; the retailer page is always the reference.